Version: v3.0.x LTS
Customizing Gateway retry policy
Customizing Gateway retry policy
Use the following procedure to change the Gateway retry policy.
Role: system programmer
All requests are disabled as the default configuration for retry with one exception: the server retries GET
requests that finish with status code 503
.
- Open the
zowe.yaml
configuration file. - Configure the following properties:
- components.gateway.ribbon.retryableStatusCodes
This property provides a list of status codes, for which the server should retry the request.
Example: components.gateway.ribbon.retryableStatusCodes: "503, 404"
- components.gateway.ribbon.OkToRetryOnAllOperations
Specifies whether to retry all operations for this service. The default value isfalse
. In this case, onlyGET
requests are retried if they return a response code that is listed inribbon.retryableStatusCodes
. Setting this parameter totrue
enables retry requests for all methods which return a response code listed inribbon.retryableStatusCodes
.
note
Enabling retry can impact server resources due to request body buffering.
-
components.gateway.ribbon.MaxAutoRetries
Specifies the number of times a failed request is retried on the same server. This number is multiplied withribbon.MaxAutoRetriesNextServer
. The default value is0
. -
components.gateway.ribbon.MaxAutoRetriesNextServer
Specifies the number of additional servers that attempt to make the request. This number excludes the first server. The default value is5
.
- Restart Zowe.